Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

[Example of assessment grades: not implemented, implemented, partially implemented, in implementation, to be clarified]

ID

Group

Type

Description

Assessment

1

Technical Implementation

Authorization

Role-based security is used in the web-application to differentiate users that can read data, users that can write data and users that can configure/administer the system.


2

Technical Implementation

Authentication

Users are authenticated through username and password when accessing the software.


3

Technical Implementation

Authentication

Usernames are limited to the following characters: A-Z, a-z, 0-9


4

Technical Implementation

Authentication

The application has login and logout functionalities.


5

Technical Implementation

Authentication

Logout functionality is available in all the pages of the web-application.


6

Technical Implementation

Authentication

Application access passwords should have at least 8 characters long and at least one of the following character sets: space, A-Z, a-z, 0-9, !"#$%&'()*+,-./:;<=>?@[\]^_`{|}~


7

Technical Implementation

Authentication

Application access passwords do not use dictionary words.


8

Technical Implementation

Authentication

Application access passwords must be changed every 2 months, otherwise user access is blocked.


9

Technical Implementation

Authentication

Accounts that have not logged in for 2 months are blocked.


10

Technical Implementation

Authentication

After 3 wrong passwords are entered for a valid login within one day, the respective user account is blocked.


11

Technical Implementation

Authentication

After 10 minutes of innactivity the user is logged out.


12

Technical Implementation

Authentication

‘Admin’ or ‘Administrator’ logins do not exist. An administrator (user that can access the application administration area) has a regular account name as any other user (e. g.: ‘gcastro’), the only difference being in the privileges that are granted.


13

Technical Implementation

Authentication

User with administration role has to provide his login and password again when performing administration actions that imply the change or deletion of data.


14

Technical Implementation

Auditing

The web-application has Audit Trail functionality that records WHO did WHAT (data entered/changed/deleted, configurations changed, logins, logouts) and WHEN (server timestamp). No debug messages are recorded. Only new information can be written and older records cannot be rewritten or delete. The Audit Trail is only accessed by administrators.


15

Technical Implementation

Authorization

Only users with Administrator role can access the Audit trail.


16

Technical Implementation

Authorization

Only system administrators can unblock an account.


17

Technical Implementation

Authorization

To run the application or connect it to webserver or database the least privileged accounts possible are used.


18

Technical Implementation

Authorization

User accounts are assigned just enough privileges to perform their tasks.


19

Technical Implementation

Authorization

Users are not administrators or vice versa.


20

Technical Implementation

Encryption

Patient identification data is transmitted encrypted.


21

Technical Implementation

Encryption

Patient identification data is stored encrypted in the database.


22

Technical Implementation

Encryption

User credentials are transmitted encrypted.


23

Technical Implementation

Encryption

User credentials are stored encrypted in the configuration files and in the database. Files containing cryptographic keys have restrictive file perimissions.


24

Technical Implementation

Encryption

Data encryption is performed using proven cryptographic services provided by platform (e. g.: OpenSSL)


25

Technical Implementation

Client-Server Communication

The web-application runs over HTTPS and each user has his own HTTPS certificate that authentifies him/her when interacting with the application server.


26

Technical Implementation

Client-Server Communication

HTTP POST is used instead of GET to submit forms.


27

Technical Implementation

Exceptions

Exceptions thrown during application execution are handled and logged; and only generic, harmless error messages are returned to the user.


28

Technical Implementation

Validation

All input available in the web-application (query strings, form fields, cookies) are validated for type, length, format and range in the different software layers.


29

Documentation

Manuals

User Manual (detailing how to use the system) exists.


30

Documentation

Manuals

Technical Manual (detailing system architecture, installation/configuration and maintenance) exists.


31

Physical Infrastructure

Server rooms

The servers in which the application is deployed are physically located in self-purpose server rooms.


32

Physical Infrastructure

Server rooms

The server rooms are locked and only authorized personnel can access them.


33

Physical Infrastructure

Server rooms

The server rooms have a constant temperature around 20-21°C.


34

Physical Infrastructure

Server rooms

The server rooms have fire prevention systems (such as alarms or fire extinguishers).


35

Physical Infrastructure

Server rooms

The server rooms have cleared walking pathways for personnel, in order that these do not face the risk of tripping on cables or devices.


36

Physical Infrastructure

Server rooms

Physical access to devices interfaces and cables within the server rooms are possible without moving equipment.


37

Physical Infrastructure

Server rooms

Server rooms are professionally cleaned at least once every three months.


38

Physical Infrastructure

Equipment

Electrical devices in the server rooms are protected against voltage spikes (e. g.: through a surge protector).


39

Physical Infrastructure

Equipment

In the event of a power failure, power supply is still assured for the electrical equipment in the server rooms (through uninterruptible power supply (UPS) and/or a backup generator)


40

Physical Infrastructure

Equipment

Cables are not stretched, tightly tied or bended.


41

Physical Infrastructure

Equipment

Cables running in parallel are tied together.


42

Physical Infrastructure

Equipment

Technical manuals are available for the devices present in server rooms.


43

Physical Infrastructure

IT Infrastructure

Servers heat dissipation exits are not blocked.


44

Physical Infrastructure

IT Infrastructure

Hardware firewalls are used at the "entry" of the clients and servers networks and are properly configured in order to analyse and filter data packets.


45

Physical Infrastructure

IT Infrastructure

The servers where the application is deployed use disk protection technology such as RAID.


46

Infrastructure - Network

Concept

An Intrusion Detection and Prevention System is operational within client and server networks in order to monitor network and/or system activities for malicious activities and policy violations.


47

Infrastructure - Network

Configuration

Routers at the networks at client and server sides are configured to restrict their responses to footprinting requests.


48

Infrastructure - Network

Configuration

Operating systems at client and server sides are configured to prevent footprinting by disabling unused protocols and services as well as unnecessary ports.


49

Infrastructure - Network

Configuration

Routers at the entry of the network at client and server levels filter incoming packets that appear to come from an internal IP address of the network.


50

Infrastructure - Network

Configuration

Routers at the entry of the network at client and server levels filter outgoing packets that appear to originate from an invalid local IP address.


51

Infrastructure - Host

Required software

Required software to run the application (operating system, frameworks, etc.) is installed and configured.


52

Infrastructure - Host

Required software

Anti-malware & anti-virus software is installed at both server and client machines.


53

Infrastructure - Host

Authentication

Passwords to access servers, client computers and supporting software (e. g.: database management system) must include at least 8 characters, including numbers, both upper and lower case letters, and specials characters.


54

Infrastructure - Host

Authorization

System commands, files and utilities within the servers are locked down with restricted Access Control Lists.


55

Infrastructure - Host

Configuration

Web server application rejects URLs with “../”.


56

Infrastructure - Host

Configuration

Functionality that enables the user to ask the browser to remember his/her credentials (login, password) for application access is disabled.


57

Infrastructure - Host

Configuration

Application configurations are not accessible to anyone besides system administrators and the application itself.


58

Processes

SOPs

Relevant operational SOPs are available (for Backup and Restore procedures, Disaster Recovery, Incident Management, Operational Change & Configuration Management, Performance Monitoring, Security Management, System Administration, User Support) and are followed.


59

Processes

Backups

Data backups are automatically performed every night on the ‘production’ data (including application data, configurations and audit trail records) and stored in more than one geographical location.


60

Processes

Required software

Required software to run the application (operating system, frameworks, etc.) on the server and on the client machines is not updated automatically, and is tested before deployment.


61

Processes

Privileges

Users receive a security role within the application that uniquely allows them to perform their work and nothing more.


62

Processes

Configuration

Security related configuration settings for software and hardware devices is reviewed for adequacy at installation and at least twice per year.


63

Processes

Authentication

Application logins are unique for each user. There are no shared logins.


64

Processes

User Behaviour

Logout: user is recommended to close session and clear any cookies left on the browser